• 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
  • 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
  • 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
  • 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
  • 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
  • 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System

5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System

Material: Aluminum
Usage: for Manufacture
Flow Direction: Centrifugal
Pressure: High Pressure
Certification: RoHS, ISO, CE, CCC
Color: Silver/ Golden
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (29)
  • Overview
  • Technical Paramater
  • Main Features
  • Performance Curves
  • Dimensions
  • Accessories
  • Installation Instructions
Overview

Basic Info.

Model NO.
GHBH 7D5 36 2R8
Frequency
50Hz/60Hz
Output
5.5kw
Protection Class
IP 54
Insulation Class
F
Certificates
SGS/RoHS/CE/ISO9001
Warranty
2 Years
Transport Package
Standard Export Package
Specification
7.5hp Goorui blower
Trademark
Goorui
Origin
China
HS Code
8414100090
Production Capacity
250/Day

Product Description

5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
Technical Paramater

Side Channel Blowers GHBH 7D5 36 2R8 Parameters:

Product Name 5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System
Model No. GHBH 7D5 36 2R8
Frequency 50Hz 60Hz
Rated Power 5.5kW 6.3kW
Rated Voltage 345-415△/600-690Y(V) 380-480△/660-720Y(V)
Rated Current 13.3△/7.7Y(A) 13.3△/7.7Y(A)
Max Airflow 520m³/h 620m³/h
Max Vacuum -280mbar -210mbar
Max Pressure 260mbar 200mbar
Sound 74db(A) 78db(A)
Weight 83kg 83kg
 
Main Features

Main Features of Goorui Regenerative Blower:
1. Adopt SKF & NSK bearing.
2. ADC12 aluminum alloy(same to BMW's wheel hubs)
3. Random installation( vertical or horizontal)
4. Insulation class: F, Protection class: IP54
5.100% oil free air delivery ( Impeller connected to the motor directly, without any oil lubricating)
6. No routine maintenance (whithout wheel gear and belt, don't need to do maintenance towards those parts)
7. Quiet operation, low noise(adopt low noise motor, meanwhile inlay muffler is available if lower noise required)
8. Variable output control(pressure or vacuum)
9. Pulsation-free compression(use quakeproof footstand)
10. Long term durability(24H running)
11. All products are strictly tested before leaving the factory
12. CE, UL, CCC, RoHS, ISO9001 certified.

Our successful client
1 Goorui High Pressure Blower is excludsively used for Qinghai-Tibet railway project.
2 Goorui blowers are widely used by government sectors, university, Training centers, Colleges, research institutes, state-owned enterprises and many private companies including Chinese Academy of Sciences, State Oceanic Administration, State Nuclear Power Technology Corporation (SNPTC) , China Academy of Machinery Science and Technology (CAM),Shanghai Jiao Tong University,Huazhong University of Science and Technology,Zhe Jiang University,Sun Yat-Sen University, Coca-Cola, Unilever. China National Petroleum Corporation(CNPC) and Inner Mongolia Yili Industrial Group Co., Ltd.
3,Successful customer testimonials: Koch-Prasad India,SACMI,MOTAN COLORTRONIC,PIOVAN,Republic sales.

Cooperative corporations:
Unilever, Chinese Academy of Sciences, Uni-President Enterprises, etc

Marketing Service
We offer side channel blowers/vacuum pumps with excellent quality and competetive price.
Meanwhile, our technicists are available to assist any of your problem. Our sales will be online to fullfill any of your requirement.

After-sale Service
12-months warranty were available for all of our products. When problem occurs, clear photos and accurate statement are needed for our specialist to analysis the cause of the problem with your engineers. If it all due to motor itself, we will find out the root cause and send you a new component to replace the bad one or change a motor for you totally free of charge. While for other reasons, we will provide professional maintenance suggestion, and send you the components with corresponding charge if you need.

Performance Curves

5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System

Dimensions

5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System

Accessories

5500W Double Stage Side Channel Blowers for Vacuum Lifting and Clamping System

Installation Instructions

INSTRUCTIONS
1. It should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
2. The direction of rotation of the impeller must be consistent with the direction of the pointed tip marked on the fan cover.
3. When working, the working pressure should not be greater than 8 kPa, so as to avoid excessive heat generation of the air pump and damage to the air pump caused by motor overcurrent.
4. It is strictly forbidden for solid, liquid and corrosive gas to enter the pump body.
5. The filters and silencers at both ends of the air inlet and outlet should be cleaned in time according to the situation to avoid clogging and affecting use.
6. The external connection of the air inlet and outlet must be connected by a hose (rubber tube, plastic spring tube).


PRECAUTIONS
1. Flat washers and spring washers must be used to tighten the screws.
2. It is best to use rubber buffer rubber to bear the weight of the vortex air pump, especially the high-power vortex air pump, which is indispensable.
3. For some occasions that require noise, a silencer can be installed to reduce the noise (generally down, about 5 dB), the silencer is installed at the end of the inlet duct or outlet duct.
4. For some occasions with high requirements for noise, you can add a layer of silencer cotton according to the conditions of the machine itself to meet the noise requirements on site. For details, please consult our customer service.
5. When using silencing cotton to silence the sound, pay attention to the distance between the vortex air pump and the box, pay attention to the ventilation and heat dissipation of the vortex air pump, and pay attention to using rubber cushioning to bear the weight of the vortex air pump. According to the picture, you need to consult customer service.
6. The air inlet and outlet of the vortex air pump For pipe connection, hose connection should be used to isolate vibration.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
>2000 square meters