Warranty: | 2 Years |
---|---|
Oil or Not: | Oil Free |
Structure: | Side Channel |
Exhauster Method: | Entrapment Vacuum Pump |
Vacuum Degree: | High Vacuum |
Work Function: | Mainsuction Pump |
Customization: |
---|
Suppliers with verified business licenses
Product Name | 10HP Central Feeding System Regenerative Vacuum Pump | |
Model No. | GHBH 010 36 BR8 | |
Frequency | 50Hz | 60Hz |
Rated Power | 7.5kW | 8.6kW |
Rated Voltage | 345-415△/600-690Y(V) | 380-480△/660-720Y(V) |
Rated Current | 16.7△/9.6Y(A) | 17.3△/10.0Y(A) |
Max Airflow | 900m³/h | 1050m³/h |
Max Vacuum | -200mbar | -150mbar |
Max Pressure | 180mbar | 120mbar |
Sound | 74db(A) | 78db(A) |
Weight | 91kg | 91kg |
Goorui industrial air blower's advantages:
1. More than ten years experience in the vacuum field and solution.
2. We have 36 core tech patent
3. Our product all adopted SKF and NSK bearing
4. Our product can heat-resistent up to 130°C
5. With high airflow as 2500m3/h, and surpass 1000 mbar.
6. We have passed the test of CE, RoHS and SGS
7. The max. motor capacity is more than 29KW
INSTRUCTIONS
1. It should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
2. The direction of rotation of the impeller must be consistent with the direction of the pointed tip marked on the fan cover.
3. When working, the working pressure should not be greater than 8 kPa, so as to avoid excessive heat generation of the air pump and damage to the air pump caused by motor overcurrent.
4. It is strictly forbidden for solid, liquid and corrosive gas to enter the pump body.
5. The filters and silencers at both ends of the air inlet and outlet should be cleaned in time according to the situation to avoid clogging and affecting use.
6. The external connection of the air inlet and outlet must be connected by a hose (rubber tube, plastic spring tube).
PRECAUTIONS
1. Flat washers and spring washers must be used to tighten the screws.
2. It is best to use rubber buffer rubber to bear the weight of the vortex air pump, especially the high-power vortex air pump, which is indispensable.
3. For some occasions that require noise, a silencer can be installed to reduce the noise (generally down, about 5 dB), the silencer is installed at the end of the inlet duct or outlet duct.
4. For some occasions with high requirements for noise, you can add a layer of silencer cotton according to the conditions of the machine itself to meet the noise requirements on site. For details, please consult our customer service.
5. When using silencing cotton to silence the sound, pay attention to the distance between the vortex air pump and the box, pay attention to the ventilation and heat dissipation of the vortex air pump, and pay attention to using rubber cushioning to bear the weight of the vortex air pump. According to the picture, you need to consult customer service.
6. The air inlet and outlet of the vortex air pump For pipe connection, hose connection should be used to isolate vibration.