• 0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
  • 0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
  • 0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
  • 0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
  • 0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture

0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture

Material: ADC 12
Usage: for Aquaculture
Flow Direction: Centrifugal
Pressure: High Pressure
Certification: RoHS, ISO, CE, CCC
Color: Golden
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2010

Suppliers with verified business licenses

Guangdong, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (29)
  • Overview
  • Technical Paramater
  • Main Features
  • Accessories
  • Installation Instructions
Overview

Basic Info.

Model NO.
GHBH 0D5 12 1R2
Bearing
SKF NSK
Life Span
More Than 20, 000 Hrs
Warranty
24 Months
Frequency
50/60Hz
Insulation Class
F
Protection Level
IP 54
Transport Package
Packed in Cartons
Specification
0.5HP
Trademark
Goorui
Origin
China
HS Code
8414100090
Production Capacity
350/Day

Product Description

Technical Paramater
Product Name 0.4kW 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
Model No. GHBH 0D5 12 1R2
Frequency 50Hz 60Hz
Rated Power 0.4kW 0.5kW
Rated Voltage 200-240V 220-275V
Rated Current 2.7A 3.2A
Max Airflow 80m³/h 98m³/h
Max Vacuum -110mbar -130mbar
Max Pressure 110mbar 140mbar
Sound 53db(A) 56db(A)
Weight 11kg 11kg
0.4kw 0.5HP Side Channel Blower Air Pump Ring Blower for Aquaculture
Main Features

GOORUI Side channel blowers are maintenance-free:
·External, permanently lubricated bearings
·Contactless rotating impellers
·Fan-cooled motors

GOORUI Side channel blowers are user-friendly:
·Weight-optimised design through aluminum pressure casting parts
·Possibility for a vertical or horizontal installation
·Suitability for converter operation

GOORUI Side channel blowers are environmentally friendly:
·Oil-free operation
·Low energy requirement
·Low noise emission

GOORUI Side channel blowers can be used world-wide:
·50/60Hz voltage range motors of the Iso class F
·Protection type IP55 with an integrated thermal protection switch (standard)
·CE, TUV, RoHS, CCC and ISO9001 certifications

 

Accessories

We also have some parts for your application, if you need, welcome to tell me.
Air filter: Filter the dust particles, apply to a bad environment.
Silencer: reduce blower noise 5-10db,  apply to a quiet environment.
Pressure relief valve: Control gas pressure, prevent excessive pressure, damage the machine.

 

Installation Instructions

INSTRUCTIONS
1. It should be placed in a relatively stable place, and the surrounding environment should be clean, dry and ventilated.
2. The direction of rotation of the impeller must be consistent with the direction of the pointed tip marked on the fan cover.
3. When working, the working pressure should not be greater than 8 kPa, so as to avoid excessive heat generation of the air pump and damage to the air pump caused by motor overcurrent.
4. It is strictly forbidden for solid, liquid and corrosive gas to enter the pump body.
5. The filters and silencers at both ends of the air inlet and outlet should be cleaned in time according to the situation to avoid clogging and affecting use.
6. The external connection of the air inlet and outlet must be connected by a hose (rubber tube, plastic spring tube).


PRECAUTIONS
1. Flat washers and spring washers must be used to tighten the screws.
2. It is best to use rubber buffer rubber to bear the weight of the vortex air pump, especially the high-power vortex air pump, which is indispensable.
3. For some occasions that require noise, a silencer can be installed to reduce the noise (generally down, about 5 dB), the silencer is installed at the end of the inlet duct or outlet duct.
4. For some occasions with high requirements for noise, you can add a layer of silencer cotton according to the conditions of the machine itself to meet the noise requirements on site. For details, please consult our customer service.
5. When using silencing cotton to silence the sound, pay attention to the distance between the vortex air pump and the box, pay attention to the ventilation and heat dissipation of the vortex air pump, and pay attention to using rubber cushioning to bear the weight of the vortex air pump. According to the picture, you need to consult customer service.
6. The air inlet and outlet of the vortex air pump For pipe connection, hose connection should be used to isolate vibration.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
1000000 RMB
Plant Area
>2000 square meters